Model L-B
 
....Operation: Full Open & Closed

Flow Diverter Valve
50 - 3,600 PSI
150#, 300#, 600#, 900#, 1500#
Flanges
- Ball Valve Type

A plunger actuator is used to allow free movement with contaminated system pressure. The pressure source can be an enlarged pipe section from the protected system or a large direct line from the system. The actuator does not "see" any valve friction because the clutch does not engage until the actuator takes up the clutch slack. At set point, the ball valve diverts flow.


Additional Advantages:
• You get safety without venting
..
pollution.
• No product loss by venting.
• No flare system required.
• No yearly valve testing.
• The pin obeys Euler's Law precisely
..and cannot fatigue.
• There is no set pressure variation
..with ambient temperature change
..on the pin.
• The precise pin is the sensor and
..the actuator.
• The standard accuracy is +/– 5%.
• Buckled pins can be replaced
..in minutes.
• The pin cannot fatigue


––––––––––––––––––––––––––––

Rupture Pin
Advanced Valves for Pressure Relief
Click Here

Taylor Valve
Safety Relief Valves, Chokes and Gauges
Click Here


 
 
 
Advantages:
The device operates with proven elements. Valve friction does not affect accuracy. A ball valve designed for the application is used. After diverting, the valve can be reoriented in minutes for a pin change by removing the vent plug and applying pressure to open the valve. When the valve is in its original position, change the pin. Remove auxillary pressure source and replace vent plug. The valve is now in a ready position to divert flow when the upstream pressure reaches set point.